• Home
  • Plasmafit® Revision

Plasmafit® Revision
Your solution within the Plasmafit® Family

Cementless acetabular revision

Plasmafit® Revision is an acetabular cup system for both primary treatment and revisions of differently located acetabular defect situations.

The hemispherical shape and the laser-sintered titanium structure of the acetabular cup provide high primary stability. To achieve good stability for larger acetabular defects, the design has a total of five options for anchoring screws.

In addition, Structan® Augments can be combined with the Plasmafit® Revision cup for treating larger defects.

 

Plasmafit® Revision – Characteristics

  • High grip thanks to very rough, laser-sintered titanium surface
  • Cup design offering several options for screw anchoring
  • Two cranial oblong holes for greater flexibility of screw fixation
  • The hex connection offers rotational stability during cup implantation
  • Roughened surface of inner cone for rotationally stable liner fixation

 

Plasmafit® Revision – Combinations

  • Vitelene® highly crosslinked polyethylene liners with vitamin E
  • Six liner options for individual fitting solutions
  • Free 360° positioning of the liners
  • Fixation screws ø 6.5 mm
  • Combination with Structan® Augments
Read more

Cementless acetabular revision

Plasmafit® Revision is an acetabular cup system for both primary treatment and revisions of differently located acetabular defect situations.

The hemispherical shape and the laser-sintered titanium structure of the acetabular cup provide high primary stability. To achieve good stability for larger acetabular defects, the design has a total of five options for anchoring screws.

In addition, Structan® Augments can be combined with the Plasmafit® Revision cup for treating larger defects.

 

Plasmafit® Revision – Characteristics

  • High grip thanks to very rough, laser-sintered titanium surface
  • Cup design offering several options for screw anchoring
  • Two cranial oblong holes for greater flexibility of screw fixation
  • The hex connection offers rotational stability during cup implantation
  • Roughened surface of inner cone for rotationally stable liner fixation

 

Plasmafit® Revision – Combinations

  • Vitelene® highly crosslinked polyethylene liners with vitamin E
  • Six liner options for individual fitting solutions
  • Free 360° positioning of the liners
  • Fixation screws ø 6.5 mm
  • Combination with Structan® Augments