• Home
  • Interventional Vascular Therapy
  • Vascular Implants and Specialities
  • Vascular Surgery
  • Specialities
  • Insitucat®

Insitucat®
Vein valve cutter

Insitucat® vein valve cutter is used for the atraumatic incision of vein valves as a preparatory step in in-situ bypass surgery. Insitucat® valvulotome consists of a polyfilament, plastic-coated guide wire. Two conical plastic olives are attached at one end. The upper olive represents the negative imprint of the venous valve sinus and has a sharp plastic cutting edge, which incises the valve when retracted. Insitucat® valvulotome is a single use product.


Advantages


Conical formed plastic olives

  • prevents slippage into tributary branches and damage to the intima


Sharp plastic cutting edge

  • minimal damage to the endothelium; the valve flaps are incised in an atraumatic manner


Polyfilic, flexible, plastic-coated guide wire

  • excellent handling and manoeuvrability
  • no memory effect, therefore no pressure against the wall ofthe vessel


Sterile double packaging

  • minimal space is required on the instrument table
  • Insitucat® can be introduced directly from the dispenser into the vessel


Single use product

  • Highest possible securityfor surgeons and patients


Indication
 

Insitucat® may be used for the atraumatic elimination of the venous valves for the femoral-popliteal and femoral-crural in situ bypass.


Note
 

Product range: Insitucat® is available in the diameters 2, 2.5, 3, 3.5, 4, 4.5, and 5 mm.

Read more

Insitucat® vein valve cutter is used for the atraumatic incision of vein valves as a preparatory step in in-situ bypass surgery. Insitucat® valvulotome consists of a polyfilament, plastic-coated guide wire. Two conical plastic olives are attached at one end. The upper olive represents the negative imprint of the venous valve sinus and has a sharp plastic cutting edge, which incises the valve when retracted. Insitucat® valvulotome is a single use product.


Advantages


Conical formed plastic olives

  • prevents slippage into tributary branches and damage to the intima


Sharp plastic cutting edge

  • minimal damage to the endothelium; the valve flaps are incised in an atraumatic manner


Polyfilic, flexible, plastic-coated guide wire

  • excellent handling and manoeuvrability
  • no memory effect, therefore no pressure against the wall ofthe vessel


Sterile double packaging

  • minimal space is required on the instrument table
  • Insitucat® can be introduced directly from the dispenser into the vessel


Single use product

  • Highest possible securityfor surgeons and patients


Indication
 

Insitucat® may be used for the atraumatic elimination of the venous valves for the femoral-popliteal and femoral-crural in situ bypass.


Note
 

Product range: Insitucat® is available in the diameters 2, 2.5, 3, 3.5, 4, 4.5, and 5 mm.